Objective
CAE Services uses expert engineering to determine solutions for possible or current issues that a part may have. In this instance, the Cameo Ice Chute needed an accurate number and location of gates and drops in order for it to avoid part burns, warpage, and short shots. The biggest recommendation that CAE gave was to add flow leaders and flow restrictors to eliminate air traps.

(results in air trap)

(eliminated air trap)

Preliminary Results
- Results predicted a major air trap in the part
- Results showed a high potential for short shot in the rib
CAE Recommendations
The following recommendations were made by the CAE engineering team to change the part design.
- The rib on the ice chute portion is very thin and may result in short shots. Consider adding thickness to help it fill out. Note that adding thickness may cause sink on the functional side of the ice chute.
- CAE recommended a combination of flow leaders and flow restrictors to eliminate the air trap. These thickness changes offset in volume so there was very little change in part weight.

Final Results
The recommended changes resulted in the following:
- The rib was thickened. There were no issues with short shots in production runs.
- The fill pattern with flow leaders cut into the production part matches Moldflow predictions. The air
trap issue was corrected before it became an issue.